Wiki Markup |
---|
\\ *Benchmark problems* from the _AISC 2010 Specification for Structural Buildings_ (commentary, page 16.1-276) have been reproduced in ETABS. The intention of AISC benchmark problems is to indicate whether or not an analysis software is capable of performing rigorous second order analyses which include P-Δ and P-δ effect. [ETABS|etabs:Home] captures both sources of [nonlinear geometry|kb:P-Delta effect] with great accuracy, well within the 3% and 5% limitation of AISC. This capability is validated in the benchmark-problem results, shown below, wherein which a column is divided into segments and subjected to compression. \\ !worddavcba72aaf0cd02a75e43befd1031e218c.png|align=center,border=0! {center-text}Figure 1 - P-δ response{center-text} \\ !worddav73c94609e8a8d32659d38874dbbb67fb.png|align=center,border=0! {center-text}Figure 2 - P-Δ response{center-text} h1. See Also * [P-Delta analysis parameters|P-Delta analysis parameters] h1. Attachments * [Case 1 ETABS model |AISC stability benchmark problems^prob1.EDB] (zipped EBD file) * [Case 2 ETABS model |AISC stability benchmark problems^prob2.EDB] (zipped EBD file) |