How is the response factor calculated?
Answer: ETABS and SAP2000 compute the Response Factor calculate response factor (RF) using the following equation:RESP-FACTOR
- RF = [2.31 – 0.41 log (100 (Case + Link damping, express in ratio))] / [2.31 – 0.41 log (100 (Function damping, express in ratio))
...
- ] [1],[2]
References
- Newmark, Nathan M.; Hall, William J. Engineering monographs on earthquake criteria, structural design, and strong motion records. Berkeley, CA: Earthquake Engineering Research Institute
...
- , 1982. Print.