Wiki Markup |
---|
h1. Handling of hyperstatic moments The flexural design check for prestressed-concrete box-girder bridge superstructures fully accounts for secondary effects from [prestress-tendon|kb:Tendon] forces. Primary prestress forces are removed and demands automatically include secondary forces. Hyperstatic [load cases|kb:Load case] need not be included in design combinations. Tendons must be modeled as elements for the flexural design check. Users should create [load combinations|kb:Load combination] with prestress loading. Primary forces are calculated through subtraction of tendon force from demand. Additional concrete forces are either secondary or imposed. {hidden-content} *PrivateInternal pagespage:* * [t:Hyperstatic analysis] {hidden-content} |