Blast analysis may be performed using a time-history analysis where in which the blast load is applied through using a triangular time function which varies linearly from the . This time function should start with zero initial conditions (time and magnitude), rapidly ramp up over a small time step (perhaps 1e-4), then vary linearly from this full value to zero.