Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

For both SAP2000 and ETABS the hinge calculations use the LRFD-99 formulas for the calculation of column compressive strength. Understrength factors are ignored and the effective fy is used. Also if a steel design has been run even once or member k factors or unbraced lengths have been overwritten then the program uses the k factors and unbraced lengths that it would have used in design. If this is not the case then k =1 and unbraced length equals clear length.


Show if
groupeditors

Related Incidents:

  • Incident 65039: Axial capacity for P hinges
    • Email "Determination of axial capacity for P hinges": (is → ok, 4/16/2014, ID 13403131)