Following is a simple example of illustrating the effects of P-delta with large displacements which users can easily reproduce with their own piping stress program. Pipe section OD 6.65" wall thickness .188", A106-B, fluid contents specific gravity 1.0 (water), no insulation. 80 ft. span of unsupported pipeline divided into 5 ft. segments. Anchors on each end have moment releases with rigid fixity in all 3 translational directions. That is, anchors are rigid in global X, Y, and Z direction with no rotational restraint stiffness.

Vertical displacements displayed below for weight case only (selfweight including fluid). Right-side window is weight case with consideration of P-delta with large displacements with max vertical displacement of -8.69". Left-side window ignores is the same weight case, but ignoring P-delta effects and reports , with a max vertical displacement of -41.5", which is what other legacy piping stress programs will report. With a long flexible pipeline like this, there is catenary behavior that needs to be accounted for in which axial load is being carried by the anchors to help support the pipeline . P-delta with large displacements accounts for this catenary behavior which made quite a difference in this example..


Image Added