Nonlinear buckling can may be evaluated in SAP2000 by running using Nonlinear analysis with static analysis. This procedure takes an iterative approach while implementing P-Delta effects and Large Displacements. You can plot displacement of a selected joints vs. the applied loads to see when the structure starts softening and begins to buckle.
Modeling Tips
...
-Displacement effect. Structural response is shown by plotting selected joint displacements against load application. A softening behavior may be observed in this plot, indicating the onset of buckling, and the condition of instability which follows.
Modeling tips
- Symmetric structures. When analyzing symmetrical structures, a geometric or loading imperfection should be introduced to initiate buckling.
- Subdivision. Structural objects should be subdivided into lengths small enough to capture geometric nonlinearity. Four to eight frame or shell objects are typically necessary per span.
- Convergence. In the load-case definition, multiple output steps should be requested to improve convergence, and to better indicate buckling response. Convergence tolerance may need to be tightened, possibly to the order of 1e-6.
- Displacement control. If a structure loses load-carrying capacity, displacement control should be implemented, rather than load control. This refers to the load-case control definition, and not how the load is actually applied.
- You may need to tighten the Convergence tolerance, say to 1e-6.
- Make sure your elements are small enough to capture geometric nonlinear effects. Typically 4 to 8 frame or shell elements per span is needed.
- Some buckling cases require converting the nonlinear static analysis case Extreme conditions. When instability is severe, nonlinear static analysis should be converted to direct-integration time-history if the instability is severe analysis.
Difference
...
between Linear and Nonlinear
...
buckling
- Linear (Eigenvalue) analysis. During Linear buckling analysis
...
- , perturbations are applied to the undeformed
...
- structural configuration. A specified set of loads are observed for which deflections could induce instability under P-Delta effect. Linear buckling analysis produces a set of buckling factors and corresponding mode shapes.
...
- When loading is multiplied by these buckling factors, the resultant scaled loading conditions represent those which induce buckling. Similarly, the mode shapes are normalized
...
- displacement sets which indicate the configuration of the buckled structure
...
- .
- Nonlinear analysis. During Nonlinear-static buckling analysis
...
- , the total load
...
- is applied incrementally. Stiffness and response are evaluated at each increment.
...
- Between each displacement step, stiffness may change
...
- due to the following effects:
- P-Delta
- effect
- , which involves large tensile or compressive stresses on transverse bending and shear behavior.
- Large
- -Displacement effect, in which deformed configuration is considered when assembling the equilibrium equations.
- Nonlinear
Unlike the linear buckling analysis, the nonlinear static analysis provides a "actual response" of the structure (displacements, internal forces, etc.) for each load increment. You can review the deformation path of the structure to determine when the structure starts softening, which may be viewed as initiation of buckling.
We would recommend you to review the following sections of the CSI Analysis Reference Manual that provide good insight into this topic:
- chapter Load Cases, section Linear Buckling Analysis
- chapter Geometric Nonlinearity, section Overview
- chapter Geometric Nonlinearity, section The P-Delta Effect
...
- material behavior, in which performance incorporates inelastic response. SAP2000 implements material nonlinearity using frame hinges and nonlinear layered-shell objects.
- Comparison. Because Nonlinear-static buckling analysis considers material nonlinearity while generating buckling response, results are often more realistic than those of Linear buckling analysis. The results of Nonlinear-static analysis are indicated by a plot of deformed configuration against load application. This plot displays the softening behavior which indicates the onset of buckling.
The CSI Analysis Reference Manual is an excellent resource for information on buckling. We recommended the following chapters:
- Analysis Cases > Linear Buckling Analysis, page 315
- Geometric Nonlinearity > Overview, page 365
- Geometric Nonlinearity > P-Delta Effect, page 369