Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

This page is devoted to frequently asked questions (FAQ) related to response-spectrum analysis.

 On this page:

Table of Contents

RSA definition

What value of scale factor should be entered in the definition of a response spectrum load case?

...

  1. Define one response-spectrum curve, then save the definition by selecting Save Named Set.
  2. Use the interactive database editor to create the remaining Named Sets, one for each plot, by editing the tables within Model Definition > Other Definitions > Named Sets.
  3. Display the output table by selecting Analysis Results > Structure Output > Named Set Data.


Show if
groupeditors

Related Incidents:

  • Incident 46481: SAP Automatisierung mit API

Can damping be changed without modifying the response-spectrum function?

...

Answer: During response-spectrum analysis, loading is applied to the entire structure, though sub-grade modes will have much higher frequencies, providing minimal contribution to modal response. However, the mass participation of subgrade levels may be subtracted from the total mass.


Show if
groupeditors

Related Incidents:

  • Incident 46672: response-spectrum analysis and grade level

RSA deflection

Why is deflected configuration identical for acceleration loads applied in either direction?

...

Answer: Response-spectrum analysis generates the likely maximum response that a structure may experience in either direction. The deflected shape for a linear-add load combination which contains a response-spectrum load case will display either the minimum or maximum displacements, depending on which has the greater absolute value. Depending on the sign of loads within the load combination, displacement may be in the positive or negative direction, even for adjacent joints.

See also Deformed shape for moving load analysis.

RSA output

How are response spectra and resultant forces obtained for each mode?

...

Please note that mass is always normalized for modes, based on the database units chosen when a new model is created from templates. The GUI environment is also set to these units, as shown in the Units Box in the bottom-right corner of the display window. While interpreting results, modal amplitudes should be consistent with these database units.


Show if
groupeditors

Related Incidents:

  • Incident 43430: Obtaining relative displacements in response spectrum

How are response-spectrum curves generated from an acceleration record?

...

Answer: Von Mises stresses are computed only when results have correspondence. Response-spectrum forces do not have correspondnece correspondence when modal combinations are performed. As a result, design will proceed according to the force envelope, which is a function of the maximum values for P, M2, and M3. In reality, these maximum forces do not occur simultaneously, therefore no plot is available. If necessary, post-processing is available for modal results.


Show if
groupeditors

Related Incidents:

  • Incident 47592: Von Mises stress missing in the output table