Numerical problems or stability problems may arise during analysis. If so, the log file should be reviewed. Information may be retrieved using the standard solver, available through Analyze > Set Analysis Options > Solver Options. Numerical problems should be fully resolved before analysis results are interpreted.
When
CSI
Software encounters zero stiffness, a warning message will indicate that a small stiffness value has been assigned to allow numerical formulation to proceed. The model should still be checked to identify and remove the source of zero stiffness.
See Also
- Unknown macro: {new-tab-link}Analysis Reference Manual (Frame Element > End Releases > Unstable End Releases, page 116)
CSI
- Numerical instability