Answer: Total in-plane shear force, based on F12 response, could be estimated by modeling additional area objects along locations where total force is to be observed. Tables and graphical display would then be available. Such an approach is necessary because in-plane shear force is not generated from strip force results.

Show if
groupeditors

Related Incidents:

  • Incident 47755: SAFE-F12 total forces