Modeling Tension-Only Members

You can model tension-only members as indicated below:

  • Select all frames which you want to carry only tension
  • Use "Assign > Frame > Tension/Compression Limits" menu command to specify zero compression limit

However, please note that T/C limits are a nonlinear feature of SAP2000 and that the following applies (the information below is taken from the F1 context help launched when the "Frame T/C Limits" form is active):

Tension/Compression limits are nonlinear. Thus, the following apply:

  • Tension/compression limits will be activated in a nonlinear static or nonlinear direct-integration time-history analysis only. In general, use nonlinear analysis when tension/compression limits are present in the model.
  • If a linear analysis is performed using the stiffness at zero, the full axial stiffness (AE/L) of the element will be used as if there were no limits.
  • If a linear analysis is performed using the stiffness at the end of a nonlinear analysis, the axial stiffness will be zero (more precisely, when tension/compression limits are used, the program replaces the behavior with a very soft spring (1e-6*EA/L)) or AE/L, depending on whether the object exceeded its limits at the end of the nonlinear case.

Tension-Only Members in Moving Load Analysis

Please note that tension-only members (members with T/C limits) are nonlinear by their nature. Currently the only way to consider nonlinear properties in moving load analysis is to run step-by-step time history moving load analysis as described above. Please refer to CSI Analysis Reference Manual, chapter "Bridge Analysis", section "Step-By-Step Analysis > Time-History Analysis" for additional information.

Unknown macro: {hidden-content}

Related emails:

  • [8/11/2008 email from fh: Compression limits not enforced]
  • [8/10/2010 email from ok: When member reaches T/C limit, the stiffness used is not zero but approximately 1e-6 times the axial stiffness]